*as per BV requirement
a)
The total time (in seconds) likely to be required in order to reach and operate
the valve closing is to be calculated from the formula:
Ta=0.72d+t+300
Where,
d= 55m between the valve control in
engine room and the farthest cabin.
t= 0.75s to 30s time necessary to
close the concerned valve
Ta=0.72d+t+300
=0.72 (55) + (30) +300
=39.6 + 30 + 300
=369.6 s
b)Total
flooding time (in seconds) is to be calculated from the formula:
Te=0.275+
Where,
V= floodable volume is 178m3
(19% of the total volume where a person may transverse to the valve)
s= Area of full pipe opening
Area=
πr2
= π (0.06)2
=0.01131m2
H= 5.25m from pipe fracture to the
load line
Te=0.275
×
=0.275 ×
=0.275 × 6868.75m3
=1888 s
“Ta” is to be shorter than “Te”
Ta < Te, the flooding calculation
is acceptable.